HNSC-C-HP-S
Function: The version with an integrated time element of the HNSC-C series monitors tilt deviations from the horizontal around a tilt axis (X-axis). If a tilt deviation occurs on the X-axis that exceeds the switching angle AND persists longer than specified by the time element, a switching operation takes place.
The tilt switch will only return to its previous operating state once the tilt deviation falls below the defined switching angle again.
An indicator LED on the switch signals the status of the switching output (Switching output 1 for changeover switches).
Measuring range X-axis:
Switching point X-axis:
.
Accuracy:
Hysteresis:
Cut-off frequency:
Time delay:
Tolerance time delay:
Measuring principle:
-90°…+90°
According to customer specifications in the range
between 3° and 45° tilt
+/- 0.5°
2° +/- 0.5°
5 Hz
Selectable 1s, 2s, 3s, 5s, 7s, or 10s
20%
MEMS
Housing material:
Dimensions:
Plastic
40 x 20 x 20 mm
Operating voltage UB:
Rated voltage:
Ripple:
Rated current:
Standby current:
Switching output:
Static voltage drop:
Connection:
Cable length:
9-30 VDC
24 VDC
< 15 %
250 mA
<5 mA
According to customer specifications (see data sheet)
5V, max.
Cable with M12 connector, 4-pole, A-coded
2m
EU Directives:
.
Applied standards:
2014/30/EU EMC Directive
2011/65/EU RoHS Directive
EN 61000-6-3:2007 + A1:2011/ AC:2012 (Emissions for residential, commercial, and light industrial environments),
EN 61000-6-2:2005 + AC:2005-09 (Immunity for industrial environments)
MTTFd:
Service life:
2148 years (Normally open/closed), 2108 years (Changeover)
20 years
The specification of the MTTF/service life value does not constitute binding quality and/or durability commitments; it is merely based on experience without binding character.
These value specifications do not extend or otherwise influence the limitation period for warranty claims.